Calibration of Hardness Testers

High-precision calibration of various types of hardness testers in accordance with international standards, with full metrological traceability according to ISO/IEC 17025.

Hardness Testers | IMTlab

Calibration of hardness testers, accredited according to ISO/IEC 17025

Calibration of hardness testers ensures the accuracy and reliability of hardness measurements of materials used in laboratories, production, and quality control. We verify the metrological characteristics of hardness testers in accordance with international standards and issue a calibration certificate according to ISO/IEC 17025, with guaranteed traceability to national standards.

Ranges and accuracy classes
What we calibrate
Who this service is for
What you receive
IMTlab

We calibrate hardness testers according to the following scales:

Brinell (HB): 5–450 HB

Vickers (HV): 8–850 HV

  • microhardness: HV0.01–HV3
  • low and medium load: HV5–HV100

Rockwell: HRA: 70–93 | HRB: 25–100 | HRC: 20–70

Shore (HA): 0–100 HA

We perform calibration of hardness testers and auxiliary hardness measuring equipment, including:

  • Hardness testers using the following methods: Brinell (HB), Rockwell (HRA, HRB, HRC, etc.), Vickers (HV), Shore (HA);
  • stationary and portable hardness testers;
  • mechanical, electronic, and digital hardness testers;
  • universal hardness testers with multiple scales;
  • reference hardness specimens / hardness test blocks;
  • indenters, including ball and diamond indenters — conical and pyramidal;
  • test loading systems of hardness testers;
  • optical indentation reading systems for Vickers and Brinell methods.

Calibration is performed in accordance with international standards, with the issuance of a calibration certificate according to ISO/IEC 17025 and full metrological traceability to national standards.

Hardness tester calibration is intended for:

  • industrial enterprises in mechanical engineering, metallurgy, energy, defense, and aviation industries;
  • production quality control laboratories and technical control departments;
  • testing and research laboratories;
  • accredited and internal metrology departments of enterprises;
  • enterprises with certified management systems, including ISO 9001, ISO 14001, IATF 16949, ISO 45001, and others;
  • educational institutions and technical universities;
  • suppliers and manufacturers of metal products and materials.

Calibration ensures compliance with standard requirements, reliability of measurement results, and equipment readiness for audits and inspections.

By ordering hardness tester calibration from us, you receive:

  • an ISO/IEC 17025 calibration certificate
    with full metrological traceability to national standards;
  • confirmed hardness measurement accuracy
    for all declared methods and ranges;
  • compliance with international standards
    such as ISO, ASTM, and DIN, depending on the measurement method;
  • readiness for audits and inspections
    by certification bodies and customers;
  • reduced risk of defects and repeat testing
    thanks to reliable quality control results;
  • professional recommendations
    regarding the condition of the hardness tester, indenters, and reference specimens;
  • officially issued documentation
    suitable for use in quality management systems.

Benefits of cooperation

IMTlab

High measurement accuracy and repeatability

We use high-precision equipment and certified methods, ensuring stable and reliable results for every calibration.

IMTlab

Compliance with international standards

All work is performed in accordance with the requirements of ISO/IEC 17025, OIML, and other international standards, ensuring that the results are accepted for audits and quality control.

IMTlab

Fast turnaround times

Optimized processes and our own equipment allow us to perform calibration promptly, without delays in your production cycle.

FAQ - Calibration of Hardness Testers

What is hardness tester calibration?

Hardness tester calibration is the verification and confirmation of its metrological characteristics by comparing measurement results with reference hardness specimens in accordance with established standards.

Which hardness methods do you calibrate?

We perform calibration of hardness testers using the Brinell, Vickers, Rockwell, and Shore methods within defined hardness ranges.

Which standards is calibration performed according to?

Calibration is performed in accordance with international ISO and ASTM standards, with the issuance of a calibration certificate according to ISO/IEC 17025.

How often should a hardness tester be calibrated?

The recommended calibration interval is once every 12 months, or more frequently depending on the intensity of use, operating conditions, and the company’s internal procedure requirements.

Do you calibrate portable hardness testers?

Yes, we calibrate both stationary and portable hardness testers, including digital and universal models.

What documents do you receive after calibration?

You receive an ISO/IEC 17025 calibration certificate, which contains measurement results, uncertainty, and information on metrological traceability.

Where is calibration performed?

Calibration can be performed in the laboratory or on the customer’s premises, by agreement and provided that the environment complies with standard requirements.